Instruction Manual
Model LP and VLP MagnaValve
IM:0077 Revision: C Date: 1/11/2008
Installation of Model LP/ VLP MagnaValve
on a Abrasive Blast Cleaning Machine
Made in the USA
Electronics Inc.
56790 Magnetic Drive
Mishawaka, Indiana 46545
1-800-832-5653 (Toll Free)
Phone: 1-574-256-5001
Fax: 1-574-256-5222
Website: www.electronics-inc.com
Vedere la pagina 0
1 2 3 4 5 6 ... 12 13

Sommario

Pagina 1 - Model LP and VLP MagnaValve

Instruction Manual Model LP and VLP MagnaValve IM:0077 Revision: C Date: 1/11/2008 Installation of Model LP/ VLP MagnaValve on a Abrasive Blast

Pagina 2

10 Fig. 17 Since this application uses a 30:5 ratio cur-rent transformer the AC controller must be adjusted to read 30.0 full scale. Press and hold

Pagina 3

11 The last step of the installation is to adjust the AC controller to the same operating amperage noted before at the beginning of the installation

Pagina 4

12 Fig. 21 The amount of this cur-vature, called arc height, is an indication of the blast stream in-tensity and the value, as meas-ured on a stand

Pagina 5

13 The advantage of using the Almen strip method lies in the ability to detect the many changes that can occur in a blast machine cleaning operation

Pagina 6

2 This manual will explain how to replace the mechanical media (grit) valve on a wheel type blast cleaning machine with the new MagnaValve automatic

Pagina 7

3 Fig. 2 An air cylinder was used to open and close the original mechanical valve as shown. This air cylinder was controlled by a manually operate

Pagina 8

4 Fig. 4 This figure shows the original operating amperage level, in this case approximately 24 amps. The operator was unable to confirm if this me

Pagina 9

5 Fig. 6 Some machines will have a slide gate or maintenance gate located above the me-chanical valve. This should be closed to allow removal of t

Pagina 10

6 Fig. 8 Once the bolts are removed, extract the valve from the machine. Be careful. The valve is heavy and may contain some shot that may spil

Pagina 11

7 Fig. 10 The adapter plates should be preinstalled onto the MagnaValve and the assembly installed as a single unit, The entire MagnaValve assembl

Pagina 12

8 Fig. 12 The cable fastens to the mating con-nector. The cable should be routed in either flexible or rigid conduit. In some installations where

Pagina 13

9 Fig. 16 Apply control power circuit. Caution: be sure all wiring has been properly completed and that no shock hazard exists. The AC controller i